File:Electromyographic recording at adductor pollicis muscle and stimulation of the ulnar nerve.jpg

Page contents not supported in other languages.
This is a file from the Wikimedia Commons
From Wikipedia, the free encyclopedia

Original file(3,872 × 2,592 pixels, file size: 5.43 MB, MIME type: image/jpeg)

Summary

Description
English: Electromyography is a form of quantitative neuromuscular function monitoring. Electromyography can be used to monitor the effects of and recovery from muscle relaxants when used as part of general anaesthesia.

In this photograph the brown and white electrodes stimulate the ulnar nerve. The brown negative electrode is always placed distally on the nerve. The green electrode is placed over the muscle the compound evoked muscle action potential is to be recorded from.

https://www.flickr.com/photos/29056374@N04/6102498133

Stimulating Electrodes:

White positive

Brown Negative

Recording electrodes:

Black Earth

Green Recording EMG electrode

Red Neutral EMG electrode

EMG electrodes: Protocol for PORC study abductor digiti minimi Stimulation Electrodes: Type: Red Dot ™ Ag/AgCl paediatric micropore™ backed electrodes (3m™) Skin Preparation. Clean, dry, degreased and abraded. Properly prepared skin is essential to provide sufficient current density to obtain supramaximal stimulation. The skin is prepared to remove excess hair, light abrasion to remove some of the stratum corneum and cleaning with alcohol to remove oils will reduce the skin resistance to obtain supramaximal stimulation with the surface electrodes. Types of Electrodes: The stimulating area of the Ag/AgCl conducting electrodes is important and the contact area of the stimulating electrode should be 7-11 mm in diameter. Distance between electrodes The distance between the centres of the stimulating electrodes should be 3 to 6 centimetres. Polarity of electrodes: The negative electrode should be placed distally: Duration of stimulus Stimulus should be a square wave and duration should be 200 microseconds and should be provided as a supramaximal stimulus. Skin Temperature and Core temperature: Changes in temperature at the neuromuscular monitoring site may affect the response to nerve stimulation. Central temperature should be > 35 degrees Celsius and skin temperature > 32 degrees Celsius. Placement of the Stimulating electrodes over the ulnar nerve. Electrodes ( Red Dot ™ Ag/AgCl paediatric micropore™ backed electrodes (3m™) will be attached to the volar (Palmar) side of the distal forearm over the ulnar nerve with the negative (stimulating) BROWN electrode positioned on the lateral side of the flexor carpi ulnaris tendon one to two centimetres proximal to the proximal wrist skin crease and the other positive WHITE electrode placed slightly offset (to ensure span over the ulnar nerve) 3 cm proximal.


The ulnar artery runs with the ulnar nerve and can be palpated to confirm the correct position of the placement of the negative stimulating electrode.



RNMB is defined as a TOFR <0.9 on 2 readings (that vary by less than 10%) taken 15 seconds apart. The BLACK neutral electrode should be applied in the midline of the proximal wrist crease.

RECORDING ELECTRODES The Abductor Digiti Minimi (ADM) recording electrodes: Green – recording electrode is placed over the main muscle bulk of the ADM on the medial (ulnar) aspect of the hand. Red – Neutral electrode is placed over the middle or intermediate phalynx joint of the fifth finger on the medial or volar aspect.

A supra-maximal stimulus is applied and an acceptable waveform has a smooth, two phase profile with a well defined initial upward deflection.
Date
Source Own work
Author Paul Anthony Stewart

Licensing

I, the copyright holder of this work, hereby publish it under the following license:
w:en:Creative Commons
attribution share alike
This file is licensed under the Creative Commons Attribution-Share Alike 4.0 International license.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.
  • share alike – If you remix, transform, or build upon the material, you must distribute your contributions under the same or compatible license as the original.

Captions

Electromyography is a form of quantitative neuromuscular monitoring and it is used to assess the effects of muscle relaxants that may be used in general anaesthesia.

Items portrayed in this file

depicts

8 March 2016

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current11:11, 15 January 2019Thumbnail for version as of 11:11, 15 January 20193,872 × 2,592 (5.43 MB)Paulstewart77User created page with UploadWizard
The following pages on the English Wikipedia use this file (pages on other projects are not listed):

Global file usage

The following other wikis use this file:

Metadata